Survey Status
Survey Status Info
KURTARMA-6
GENERAL INFO
Ship Name:
KURTARMA-6
TL Register Number:
G-1383
Vessel Status:
IN CLASS
/
IN SERVICE
IMO No:
9463176
Flag:
THE REPUBLIC OF TÜRKİYE
Call Sign:
TCTM9
Port Of Registry:
İSTANBUL
Ship Type:
TUG
GMDSS Navigation Area:
A1+A2
SHIP OWNER
Ship Owner:
KIYI EMNİYETİ GENEL MÜDÜRLÜĞÜ
Address:
BEYLERBEYI MAH. ABDULLAHAĞA CAD. NO : 16/A BEYLERBEYİÜSKÜDAR
Fax No:
90216 532 34 61
E-Mail:
leyla.pehlivan@kiyiemniyeti.gov.tr
Phone:
90216 531 40 00
SHIP MANAGER
Manager:
KIYI EMNİYETİ GENEL MÜDÜRLÜĞÜ
Address:
BEYLERBEYI MAH. ABDULLAHAĞA CAD. NO : 16/A BEYLERBEYİÜSKÜDAR
Fax No:
90216 532 34 61
E-Mail:
leyla.pehlivan@kiyiemniyeti.gov.tr
Phone:
90216 531 40 00
CLASS NOTATION
Hull:
+ 1A5 ESCORT TUG (70, 8) (95, 10)
Machinery:
+ M FF1/2
MAIN DIMENSIONS
Lenght Between Parpendiculars (Lbp):
36
m
Breath Moulded:
12
m
Moulded Depth:
4.5
m
Summer Freeboard (d):
1008
mm
Gross Tonnage (GT):
472
Net Tonnage (NT):
142
Dwt:
330.31
t
CONSTRUCTION DETAILS
Keel Laying Date:
01.09.2006
Launching Date:
Building Date:
13.05.2008
ShipYard-Building Place-ShipYard-Building Place:
Akar Grup Deniz Taşımacılığı Sanayi Ticaret Ltd. Şti. - Pendik, İstanbul-Türkiye
Cargo Hold / Tank Count:
15
Continuous Machinery Survey:
false
EQUIPMENT
Anchor Weight:
900
kg
Cable Length:
358
m
Cable Quality:
K 3
Cable Diameter mm.:
24
mm
Anchor Number:
3
MACHINERY
Propelling Type:
Internal Combustion Engine
Description
Manufacturer
Type
Serial No
Power
Revulation
Main Engine Nr.1
ABC
12VDZC
13144
2650.0 kW
/
3552.0 BHp
1000 rpm
Main Engine Nr.2
ABC
12VDZC
13145
2650.0 kW
/
3552.0 BHp
1000 rpm
Description
Manufacturer
Type
Serial No
Power
Revulation
Aux Engine (D/G Nr.1)
Volvo Penta
D12D-A MG
1012626062
310.0 kW
1500 rpm
Aux Engine (D/G Nr.2)
Volvo Penta
D12D-A MG
1012625980
310.0 kW
1500 rpm
Aux Engine (D/G Nr.3)
Volvo Penta
D5A-TA
1510442838
92.0 kW
1500 rpm
Aux Engine (D/G Nr.4)
Mitsubishi
S16R-MPTK
13466
1650.0 kW
1800 rpm
Description
Manufacturer
Type
Serial No
Power (kVA)
Voltage/Frequency
Alternator (D/G Nr.1)
İŞBİR ELEKTRİK
SGB 608/4-T
340.0 kVa
400 V
Alternator (D/G Nr.2)
İŞBİR ELEKTRİK
SGB 608/4-T
340.0 kVa
400 V
Alternator (D/G Nr.3)
İŞBİR ELEKTRİK
SGB 437/4-T
100.0 kVa
400 V
Propulsion Thruster
(Cycloidal)
AFT-PORT
Propulsion Thruster
(Cycloidal)
AFT-STBD
CLASSIFICATION CERTIFICATES
Certificate Name
Issue Date
Expire Date
Extend
Certificate Type
Certificate of Class
01.08.2023
05.07.2027
-
Full Term
* Certificate was issued by Administration.
FLAG CERTIFICATES
Certificate Name
Issue Date
Expire Date
Extend
Certificate Type
International Load Line Certificate (1966)
01.08.2023
05.07.2027
-
Full Term
Cargo Ship Safety Radio Certificate
06.12.2024
05.07.2027
-
Full Term
International Oil Pollution Prevention Certificate (Type A)
01.08.2023
05.07.2027
-
Full Term
Record of Construction and Equipment for Ship Other Than Oil Tankers (Form A)
01.08.2023
-
Full Term
International Sewage Pollution Prevention Certificate
01.08.2023
05.07.2027
-
Full Term
International Air Pollution Prevention Certificate
01.08.2023
05.07.2027
-
Full Term
International Energy Efficiency Certificate
01.08.2023
-
Full Term
International Anti-Fouling System Certificate
14.03.2023
-
Full Term
* * Survey was carried out by Losing Society.
PERIODIC CLASS SURVEYS
Survey Name
Last Survey
Next Survey
Survey Range
Postponed
Status
Class Renewal Survey - Hull
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Class Renewal Survey - Machinery
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Class Intermediate Survey
21.04.2025
05.07.2030
05.04.2029
-
05.10.2030
-
Class Annual Survey
01.10.2026
05.07.2027
05.04.2027
-
05.07.2027
-
Bottom Survey - Dry Dock -
14.03.2023
05.07.2027
-
05.07.2027
-
Bottom Survey - In Water -
21.04.2025
05.07.2027
05.04.2027
-
05.10.2027
-
Propulsion Thruster Survey (Cycloidal) Aft-Stbd
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Propulsion Thruster Survey (Cycloidal) Aft-Port
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
NOTE: Renewal Survey may be commenced at the 4th Annual Survey and be programmed with a view to completion by the 5th annual date.
ISPS AUDITS
No Record Found...
ISM AUDITS
No Record Found...
MLC INSPECTIONS
No Record Found...
* Survey was carried out by Losing Society or Administration.
STATUTORY SURVEYS
Survey Name
Last Survey
Next Survey
Survey Range
Postponed
Status
Load Line Renewal Survey
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Load Line Annual Survey
01.10.2026
05.07.2027
05.04.2027
-
05.07.2027
-
Cargo Ship Safety Radio Renewal Survey
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Cargo Ship Safety Radio Periodical Survey
01.10.2026
05.07.2027
05.04.2027
-
05.07.2027
-
Marpol Annex I Renewal Survey
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Marpol Annex I Intermediate Survey
21.04.2025
05.07.2030
05.04.2029
-
05.10.2030
-
Marpol Annex I Annual Survey
01.10.2026
05.07.2027
05.04.2027
-
05.07.2027
-
Marpol Annex IV Renewal Survey
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Marpol Annex VI Renewal Survey
14.03.2023
05.07.2027
05.04.2027
-
05.07.2027
-
Marpol Annex VI Intermediate Survey
21.04.2025
05.07.2030
05.04.2029
-
05.10.2030
-
Marpol Annex VI Annual Survey
01.10.2026
05.07.2027
05.04.2027
-
05.07.2027
-
International Energy Efficiency Certificate Initial Survey
22.01.2014
-
-
-
Antifouling System Endorsement of the Records
14.03.2023
-
-
-
CONTINUOUS MACHINERY SURVEYS
No Record Found...
Executing...